What Is Part Number for the Fuel Shut Off Valve for the Blue Max 4000
Maximum engine efficiency for on- and off-highway applications.
The requirements for fuel purity to operate modern diesel engines are constantly increasing.
Hengst Filtration stays on top of the latest trends in engine technology and has developed a modular system for fuel filtration. It consists of basic variants available as standard and can be customized by five innovative add-ons.
Blue.maxx is a fuel filter system that is characterized in particular by very effective water separation and can be optimally adapted to any application.
- Overview
- Features
- Add-Ons
- Advantages
- Video
- Article and Flyer
- Contact
- Newsletter
Overview
Hengst Filtration offers three different Blue.maxx basic sizes for a wide range of volume flow rates.
Features
Blue.maxx 200
Blue.maxx 300
Blue.maxx 450
| Blue.maxx 200 | Blue.maxx 300 | Blue.maxx 450 | |||||
| Pre-filter | Main-filter | Pre-filter | Main-filter | Pre-filter | Main-filter | ||
| Filter housing geometry data | |||||||
| Height h [mm] | 266 | 266 | 282 | 282 | 367 | 319 | |
| Width w [mm] | 96 | 96 | 119 | 119 | 119 | 119 | |
| Depth d [mm] | 104 | 104 | 148 | 140 | 148 | 140 | |
| Connecting thread [mm] | M16x1,5 (5x) | M16x1,5 (5x) | M16x1,5 (4x) | M16x1,5 (4x) | M16x1,5 (4x) | M16x1,5 (4x) | |
| Mechanical data | |||||||
| Volumen rate (nominal) | 200 [I/h] | 200 [I/h] | 300 [I/h] | 300 [I/h] | 450 [I/h] | 450 [I/h] | |
| Temperature | From -30 to 120 °C | From -30 to 120 °C | From -30 to 120 °C | From -30 to 120 °C | From -30 to 120 °C | From -30 to 120 °C | |
| Working pressure suction side | -0,3 … 4 [bar] | -0,3 … 15 [bar] | -0,3 … 4 [bar] | -0,3 … 15 [bar] | -0,3 … 4 [bar] | -0,3 … 15 [bar] | |
| Filtration data | |||||||
| Initial Efficiency acc. to ISO 19438 | 97 % (@ 10 μm) | 97 % (@ 4 μm) | 97 % (@ 10 μm) | 97 % (@ 4 μm) | 97 % (@ 10 μm) | 97 % (@ 4 μm) | |
| Dust holding capacity (nominal) ISO 19438 | 30 g (dp = 30kPa) | 55 g (dp = 80kPa) | 40 g (dp = 30kPa) | 70 g (dp = 80kPa) | 69 g (dp = 30kPa) | 105 g (dp = 80kPa) | |
| Water separation efficiency acc. to ISO 16332 (60 μm @ 0,15 %) | 99 % | - | 99 % | - | 99 % | - |
Optionally, the systems (300, 450) are also available with a heater (incl. wiring kit). Systems 200, 300 and 450 are upgradable with the following kits: water-in-fuel sensor (with wiring kit), hose connection kit, thread adapter kit and antarctic version from -40 °C to 120 °C.
Add-Ons
The basic variants can be customized by different add-ons to meet the customer's individual requirements.
- Pumps
- Heaters
- WIF sensors
- Connectors
- Filter elements
Short description
Manual hand feed pump
-
Robust piston hand feed pump
-
Up to 20 ml per stroke (more than 3 time more than membrane pumps)
Available variants
Technical details
| Operating temperature range | - 40°C … + 120°C |
| Pump volume per stroke | 13 … 20 ml / stroke |
| Suction height | 5m |
Electrical pump
-
Robust brushless vane pump
-
Guaranteed lifetime up to 4000 h
-
Optional bypass valve available
-
2-pin connector (Tyco AMP 282104-1)
-
Electrical voltage 12V & 24V
| Operating voltage | 6V … 32V DC |
| Operating temperature range | - 40°C … + 120°C |
| Working pressure range | - 35 kPa up to 600 kPa |
| Volume flow min at 40 kPa | 250 l/h |
Short description
Rod heater - Blue.maxx 100 & 200
-
Heater with one PTC mounted on a tube
-
Integrated thermoswitch to control on/off state
-
2-pin connector (Tyco AMP 282104-1)
-
Electrical voltage 12V & 24V
Available variants
Technical details
| Operating voltage | 6…16V / 18…32V AC/DC |
| Operating temp. range | - 40°C … + 120°C |
| Working pressure range | 0 … 1500 kPa |
| Nominal power | 150W |
Ring heater - Blue.maxx 300 & 450
-
Heater with four PTCs between two plates
-
Integrated thermoswitch to control on/off state
-
2-pin connector (12V - Delphi Weather Pack / 24V - Tyco AMP 282104-1)
-
Electrical voltage 12V & 24V
| Operating voltage | 6 … 16V / 18 … 32V AC/DC |
| Operating temp. range | - 40°C … + 120°C |
| Working pressure range | 0 … 1500 kPa |
| Nominal power | 200W / 260W |
Short description
Passive water-in-fuel sensor
-
Sensors work without electronics
-
External evaluation electronics required
-
Interface to ECU required
-
2-pin contacts used (Tyco Deutsch DT04-2P)
Available variants
Technical details
| Operating voltage | 3V … 36V AC/DC |
| Operating temp. range | - 40°C … + 120°C |
| Working pressure range | up to 1500 kPa |
Active water-in-fuel sensor
-
Sensors work with own electronics
-
Measured value is evaluated in sensor
-
Connection of optical sensor-signal possible
-
3-pin contacts (Tyco HDSCS 3 Pos Group A)
| Operating voltage | 9V … 32V DC |
| Operating temp. range | - 40°C … + 120°C |
| Working pressure range | up to 1500 kPa |
Short description
Quick connector SAE
-
Material: polyamide & brass
-
Type: SAE J 2044 / thread M16x1,5
-
Sealing: acc. to ISO6149 or with gasket DIN7603
-
Available in Ø 8 mm, Ø 10 mm and Ø 12 mm
Available variants
Technical details
| Operating temp. range | - 40°C … + 120°C |
| Working pressure range | up to 1500 kPa |
Quick connector VOSS
-
Material: brass
-
Type: VOSS system 246 / thread M16x1,5
-
Sealing: acc. to ISO6149 or with gasket DIN7603
| Operating temp. range | - 40°C … + 120°C |
| Working pressure range | up to 1500 kPa |
Ball-type connector
-
Material: steel
-
Type: DIN 7601 Form Q / thread M16x1,5
-
Sealing: with gasket DIN7603
| Operating temp. range | - 40°C … + 120°C |
| Working pressure range | up to 1500 kPa |
Short description
Premium 4 filter elements
-
High efficiency filter element mainly for pressure side
-
Designed for main filter application
-
Available in four sizes depending on volume flow
Available variants
Technical details
| Efficiency | >97 % @4 µm |
| Volume flow | 100 l/h … 450 l/h |
| Lifetime | >1000 h | >60.000 km |
Premium 10 filter elements
-
High efficiency filter element mainly for suction side
-
Designed for pre filter application
-
Available in four sizes depending on volume flow
| Efficiency | >97 % @10 µm |
| Volume flow | 100 l/h … 450 l/h |
| Lifetime | >1500 h | >90.000 km |
Premium 30 filter elements
-
Efficient filter element with extended lifetime
-
Designed for pre filter application, mainly for suction side
-
Available in four sizes depending on volume flow
| Efficiency | >97 % @30 µm |
| Volume flow | 100 l/h … 450 l/h |
| Lifetime | >2000 h | >120.000 km |
Single-stage water separation
-
High water separation performance
-
Regeneration after water breakthrough
-
Accumulation of water outside the filter element and drainage to water bowl
| Water efficiency new | 93 % … 100 % |
| Water efficiency aged | 20 % … 80 % |
| Compatibility | Diesel, Biodiesel, Ethanol, Synthetic fuels, Kerosine |
| Application | Suction- and pressure-side |
Multi-stage water separation
-
High and robust water separation performance by adjustable filtration-, coalescing- and draining-stage design
-
Compensating ageing and high water impact over whole filter element lifetime
-
Accumulation of water inside the filter element and drainage to water bowl through bottom
| Water efficiency new | 93 % … 100 % |
| Water efficiency aged | >80 % |
| Compatibility | Diesel, Biodiesel, Ethanol, Synthetic fuels, Kerosine |
| Application | Suction- and pressure-side |
Advantages
Blue.maxx – the most important advantages at a glance:
- High degree of customization - available at short notice
- Leading quality standards in filtration - directly visible compared to conventional Spin-on filters
- High degree of water separation over lifetime - guaranteed through innovative filter design
- Patent-protected filter elements guarantee high functional reliability & the aftermarket business
Video
Article and Flyer
Flyer zum Blue.maxx
Blue.maxx editorial article / Diesel Progress 2021 / Page 31
Contact
Do you have questions? We will be glad to assist you.
Or stay connected via LinkedIn
Newsletter
← Back
Source: https://www.hengst.com/en/products/fuel-filter-modules/bluemaxx/
Belum ada Komentar untuk "What Is Part Number for the Fuel Shut Off Valve for the Blue Max 4000"